2083 -3293kW Output

This burner is suitable for use on natural gas and LPG (Towns gas and biogas on request) with-

  • two stage high/low
  • or modulating operation.

All N series burners are custom-built and designed for easy maintenance. This range is typically suited for high resistance, hot water and steam boilers.

Information

Key Features:

  • Quick and easy installation
  • Reliable and trouble free operation
  • Industry standard components available
  • Most components can be easily accessed allowing for easy maintenance.

Also available:

  • Larger gas trains
  • Electronic Micro Modulating control
  • Variable speed drive to reduce power consumption and noise levels.

All N series burners have been design in accordance with EN676 and EN267.

Information

Type

NG125

Capacity

kW

2120-2751

Fan Motor

V/ph/Hz

380-420/3/50

125-36

125-41

Motor

kW

7.5

11

Start Current

A/each phase

57

72

Run Current

A/each phase

15.6

22.8

Cable size

mm2

4

6

Fuse

HRC (A)

25

30

Control unit

LFL

Operation Options

2 Stage / Mod

Flame monitoring

UV Cell

Air damper motor

Max inlet gas pressure

mbar

300

Noise @ 1m

dBA

92

94

Gross weight

kg

330

Volume

m3

2.344